Review




Structured Review

Volcano Corporation intravascular ultrasound
Under <t>intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Intravascular Ultrasound, supplied by Volcano Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ultrasound/pmc13054279-19-14-19
Average 86 stars, based on 1 article reviews
intravascular ultrasound - by Bioz Stars, 2026-09
86/100 stars

Images

1) Product Images from "Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection"

Article Title: Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

doi: 10.1016/j.jvscit.2026.102212

Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Figure Legend Snippet: Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Techniques Used: Dissection, Modification, Injection

Related Articles

Injection:

Article Title: Total Endovascular Iliocaval Reconstruction Using Polytetrafluoroethylene Stent-Graft Placement for the Treatment of Inferior Vena Cava Resection.
Article Snippet: Resection of the inferior vena cava (IVC) is a rare surgical technique that is occasionally combined with nephrectomy in the setting of renal malignancy with intravascular tumor extension.. While this may be fairly well tolerated in some patients due to extensive collateralization in the venous system, there is a clear potential for lower extremity venous insufficiency and deep vein thrombosis (DVT).. This report describes a patient who underwent right nephrectomy and segmental IVC resection from the subhepatic space to the iliac confluence, which was complicated by profoundly symptomatic lower extremity DVT and gastrointestinal hemorrhage due to system-to-portal shunting.

other:

Article Title: Gianturco Z-stent placement for the treatment of chronic central venous occlusive disease: implantation of 208 stents in 137 symptomatic patients
Article Snippet: Once the obstruction was traversed, intraluminal position was confirmed using contrast venography (n=137, 100%) and intravascular ultrasound (Volcano Corporation) (n=42, 30.7%).

Article Title: Endovascular management of early lung transplant-related anastomotic pulmonary artery stenosis.
Article Snippet: Purpose: To report the safety and short-term efficacy of endovascular interventions for symptomatic lung transplant–related anastomotic pulmonary artery stenosis (PAS).. Materials and Methods: From February 2008 to December 2011, 354 lung transplants were performed.. Pulmonary arteriography was performed in 19 patients (63% men; age, 57 y 21, mean SD; seven double-lung transplants) because of respiratory decompensation (mean 6.7 mo after transplant).

Imaging:

Article Title: No-Reflow Complicating Chronic Total Occlusion Coronary Revascularization.
Article Snippet: Objectives.. To assess the incidence of no-reflow in patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI), analyze possible causes and differential diagnoses, and identify useful management approaches.. Methods.

Dissection:

Article Title: Unique Case of Spontaneous Left Main Coronary Dissection in Second Trimester of Pregnancy Successfully Treated with Percutaneous Coronary Intervention: A Happy Ending
Article Snippet: The procedure consisted of double wiring into LAD/CX (0.014 Balance Middle Weight) passing through the true lumen of the dissection, then stenting with a 4 × 23 mm everolimus-eluting stent (Xience Pro Abbott Vascular) into an LM-LAD system, before finally rewiring (0.014 Pilot 50) into CX and stent post-expansion with a 4.5 × 15 mm non-compliant balloon (Accuforce Terumo) and lateral kissing with a 2 × 10 mm semi-compliant balloon (Euphora Medtronic) ( panel 2(a–d)). .. Intra-procedural intravascular ultrasound (Volcano Corporation) performed before and after the high-pressure non-compliant balloon showed stent struts well apposed, no residual dissection, and the persistence of mild intramural hematoma ( panel 3(a–c)). ..



Similar Products

86
Volcano Corporation intravascular ultrasound
Under <t>intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Intravascular Ultrasound, supplied by Volcano Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ultrasound/pmc13054279-19-14-19
Average 86 stars, based on 1 article reviews
intravascular ultrasound - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation opticross hd intravascular ultrasound ivus system
<t>Intravascular</t> <t>Ultrasound</t> Images of True and False Lumen (A) <t>Intravascular</t> <t>ultrasound</t> located in the false lumen demonstrating the smaller true lumen. (B) Same still image with annotation of true and false lumens.
Opticross Hd Intravascular Ultrasound Ivus System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/hd+ivus/pmc13154088-39-7-5
Average 86 stars, based on 1 article reviews
opticross hd intravascular ultrasound ivus system - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation intravascular ultrasound system
<t>Intravascular</t> <t>Ultrasound</t> Images of True and False Lumen (A) <t>Intravascular</t> <t>ultrasound</t> located in the false lumen demonstrating the smaller true lumen. (B) Same still image with annotation of true and false lumens.
Intravascular Ultrasound System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ultrasound/pm42084577-125-0-4
Average 86 stars, based on 1 article reviews
intravascular ultrasound system - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Philips Healthcare intravascular ultrasound ivus
(A–D) <t>Intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.
Intravascular Ultrasound Ivus, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ivus+ultrasound/pmc12938089-30-13-10
Average 86 stars, based on 1 article reviews
intravascular ultrasound ivus - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Philips Healthcare imaging • fluoroscopy system • eagle eye platinum digital intravascular ultrasound catheter
(A–D) <t>Intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.
Imaging • Fluoroscopy System • Eagle Eye Platinum Digital Intravascular Ultrasound Catheter, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ivus+ultrasound/pmc13112576-8-0-12
Average 86 stars, based on 1 article reviews
imaging • fluoroscopy system • eagle eye platinum digital intravascular ultrasound catheter - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation intravascular ultrasound ivus system
(A–D) <t>Intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.
Intravascular Ultrasound Ivus System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/intravascular+ultrasound/us12594438-301-15-21
Average 86 stars, based on 1 article reviews
intravascular ultrasound ivus system - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Radboud University non culprit intravascular ultrasound
(A–D) <t>Intravascular</t> <t>ultrasound</t> <t>(IVUS)</t> cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.
Non Culprit Intravascular Ultrasound, supplied by Radboud University, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/intravascular+ultrasound/culprit+infrared+intravascular+near+non+ultrasound/pm41870626-43-3-19
Average 86 stars, based on 1 article reviews
non culprit intravascular ultrasound - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

Image Search Results


Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection

doi: 10.1016/j.jvscit.2026.102212

Figure Lengend Snippet: Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Article Snippet: Through the right femoral approach, a guiding sheath (Parent Plus 60; Medikit Co) and intravascular ultrasound (IVUS; IntraSight Mobile; Volcano Corporation) were advanced, while a Rosch-Uchida needle was introduced from the left femoral sheath.

Techniques: Dissection, Modification, Injection

Intravascular Ultrasound Images of True and False Lumen (A) Intravascular ultrasound located in the false lumen demonstrating the smaller true lumen. (B) Same still image with annotation of true and false lumens.

Journal: JACC Case Reports

Article Title: Novel Use of Dual-Lumen Microcatheter for False Lumen Hematoma Decompression

doi: 10.1016/j.jaccas.2026.107511

Figure Lengend Snippet: Intravascular Ultrasound Images of True and False Lumen (A) Intravascular ultrasound located in the false lumen demonstrating the smaller true lumen. (B) Same still image with annotation of true and false lumens.

Article Snippet: Position was confirmed using a Boston Scientific Opticross HD intravascular ultrasound (IVUS) system.

Techniques:

(A–D) Intravascular ultrasound (IVUS) cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.

Journal: Radiology Case Reports

Article Title: Trans-ankle intervention can be an optimal strategy for aggressive wire recanalization in calcified atheroma and dilatation technique in common femoral artery

doi: 10.1016/j.radcr.2026.01.048

Figure Lengend Snippet: (A–D) Intravascular ultrasound (IVUS) cross-sectional image. The second guidewire (arrows) passes through a different route from the first guidewire and (E) Alphabet indicating the location of cross-sectional IVUS images.

Article Snippet: Fig 2 – dummy alt text Eagle Eye Platinum ST (PHILIPS, Amsterdam, Netherlands) intravascular ultrasound (IVUS) was performed using the first guidewire ( A– ).

Techniques:

(A and B) Optimal balloon lesion preparation on the 2 guidewire routes. (C) Final angiography demonstrating relatively good vascular patency and a favorable blood flow. (D) Magnified image of the square region shown in Fig. 4C. The alphabet indicates the location of the cross-sectional IVUS images. (E–H) Final IVUS cross-sectional image.

Journal: Radiology Case Reports

Article Title: Trans-ankle intervention can be an optimal strategy for aggressive wire recanalization in calcified atheroma and dilatation technique in common femoral artery

doi: 10.1016/j.radcr.2026.01.048

Figure Lengend Snippet: (A and B) Optimal balloon lesion preparation on the 2 guidewire routes. (C) Final angiography demonstrating relatively good vascular patency and a favorable blood flow. (D) Magnified image of the square region shown in Fig. 4C. The alphabet indicates the location of the cross-sectional IVUS images. (E–H) Final IVUS cross-sectional image.

Article Snippet: Fig 2 – dummy alt text Eagle Eye Platinum ST (PHILIPS, Amsterdam, Netherlands) intravascular ultrasound (IVUS) was performed using the first guidewire ( A– ).

Techniques: